Hi all, We are planning to use human affymetrix chip on monkey and I would like to know if it's better to use HU133 chips or HU95 chips ? For the HU133 : more recent, better design of probe (specificity, TM), more genes, but only 11 probes per gene and the probes are frequently design in the 3'UTR with a risk of a divergence between human and monkey. Tanks for your help. L. Buffat