Agilent one colour
1
0
Entering edit mode
@yogi-sundaravadanam-2312
Last seen 10.2 years ago
Hi all, I am working with Agilent one-colour array, and I find working with gProcessedSignal to be just horrible. I was just wondering if people have had experiences normalising one-colour array, and what works best. I was wondering if Background subtraction, followed by quantile normalisation is preferable? Best, Yogi [[alternative HTML version deleted]]
• 1.1k views
ADD COMMENT
0
Entering edit mode
@sean-davis-490
Last seen 3 months ago
United States
On Mon, Mar 22, 2010 at 6:23 PM, Yogi Sundaravadanam <yogi.sundaravadanam at="" agrf.org.au=""> wrote: > Hi all, > > I am working with Agilent one-colour array, and I find working with gProcessedSignal to be just horrible. I was just wondering if people have had experiences normalising one-colour array, and what works best. > > > I was wondering if Background subtraction, followed by quantile normalisation is preferable? Hi, Yogi. gProcessedSignal is background-subtracted already, I believe, but it is not normalized. Very rarely does the data from a one-color array platform come normalized between arrays, a necessary step, I think. Quantile normalization between arrays is a reasonable possibility, yes. As with any array study, you'll want to do some quality assessment both before and after normalization. Sean
ADD COMMENT
0
Entering edit mode
Hi Sean, Thanks for this. A bit off topic, but with two colour agilent array, I have been using just the LogRatio for downstream analysis. It makes me wonder if I should be normalising this as well. Sorry, but I have never worked with Agilent, and FE doesn't say much. Thanks for your help. Best, Yogi -----Original Message----- From: Sean Davis [mailto:seandavi@gmail.com] Sent: Tuesday, 23 March 2010 10:38 AM To: Yogi Sundaravadanam Cc: bioconductor at stat.math.ethz.ch Subject: Re: [BioC] Agilent one colour On Mon, Mar 22, 2010 at 6:23 PM, Yogi Sundaravadanam <yogi.sundaravadanam at="" agrf.org.au=""> wrote: > Hi all, > > I am working with Agilent one-colour array, and I find working with gProcessedSignal to be just horrible. I was just wondering if people have had experiences normalising one-colour array, and what works best. > > > I was wondering if Background subtraction, followed by quantile normalisation is preferable? Hi, Yogi. gProcessedSignal is background-subtracted already, I believe, but it is not normalized. Very rarely does the data from a one-color array platform come normalized between arrays, a necessary step, I think. Quantile normalization between arrays is a reasonable possibility, yes. As with any array study, you'll want to do some quality assessment both before and after normalization. Sean
ADD REPLY
0
Entering edit mode
On Tue, Mar 23, 2010 at 12:47 AM, Yogi Sundaravadanam <yogi.sundaravadanam at="" agrf.org.au=""> wrote: > Hi Sean, > > Thanks for this. > > A bit off topic, but with two colour agilent array, I have been using just the LogRatio for downstream analysis. It makes me wonder if I should be normalising this as well. > Hi, Yogi. You might need to look into some background on microarray data analysis. Generally, if you want to compare between microarray experiments, you'll want to do a significant amount of quality control and assessment to be sure and I think most people would agree that normalization usually improves downstream inference. In other words, QA/QC and normalization are probably necessary steps in microarray data analysis. > Sorry, but I have never worked with Agilent, and FE doesn't say much. The Agilent FE manual does not lay out an analysis recipe, I agree. However, it is useful for determining what data are represented in the FE .txt file. I would recommend having it handy when analyzing Agilent data, in any case. Sean > -----Original Message----- > From: Sean Davis [mailto:seandavi at gmail.com] > Sent: Tuesday, 23 March 2010 10:38 AM > To: Yogi Sundaravadanam > Cc: bioconductor at stat.math.ethz.ch > Subject: Re: [BioC] Agilent one colour > > On Mon, Mar 22, 2010 at 6:23 PM, Yogi Sundaravadanam > <yogi.sundaravadanam at="" agrf.org.au=""> wrote: >> Hi all, >> >> I am working with Agilent one-colour array, and I find working with gProcessedSignal to be just horrible. I was just wondering if people have had experiences normalising one-colour array, and what works best. >> >> >> I was wondering if Background subtraction, followed by quantile normalisation is preferable? > > Hi, Yogi. > > gProcessedSignal is background-subtracted already, I believe, but it > is not normalized. ?Very rarely does the data from a one-color array > platform come normalized between arrays, a necessary step, I think. > Quantile normalization between arrays is a reasonable possibility, > yes. ?As with any array study, you'll want to do some quality > assessment both before and after normalization. > > Sean >
ADD REPLY