Entering edit mode
pepere
▴
40
@pepere-6475
Last seen 5.9 years ago
Hello, After performing a general Bioconductor update to the new
version, I
noticed that now the DEXseq package 1.8.0 is giving me different
results
from prrevious version 1.6.0. As a start, its function print dots
"..." on
the stdout which was not done in the previous version. This is not a
big
issue, the problem is that now I am obtaining different results.
Generally,
the padjust values are bigger.
For example this exon:
a1 a2 a3 b1 b2 b3
EXXXX 126 90 101 81 233 225
gets different results:
geneID,exonID,dispersion,pvalue,padjust,meanBase,log2fold(b/a)
old version:
EXXXX,0.0684906370633231,0.00256847378387803,0.0321347815544768,129.94
1383199307,-0.217272839643456
new version:
EXXXX,0.0928452378435829,0.00401881761350959,0.0587521235795571,129.94
1383199307,-0.213275654796358
as you can see the old one has a padjust below 0.05 and the other
above
0.05, which is a big problem.
I had a look in the NEWS section of the DEXSeq package, but i couldn't
find
any information about major changes.
thank you very much, regards,
[[alternative HTML version deleted]]