LPE
0
0
Entering edit mode
Harry Hurd ▴ 60
@harry-hurd-591
Last seen 10.3 years ago
Hello, We have recently been trying LPE as implemented in bioconductor. We tried it for N=3 on the affy 133plus array (55K probes). The most significant results are very pleasing to the biologists (so far anyway) but in trying to do some further work to assign some FDRs, I plotted the CDF and a normal probability plot for the resulting z scores. There is a huge proportion of small values. The zscores do not look anything like normal. To what extent should the z scores look N(0,1)? The estimated sigma is about .5; should it be near 1? Does anyone have experience using LPE on a large array like the 133plus? Thanks much for any help. Harry Hurd Dept of Statistics UNC Chapel Hill [[alternative HTML version deleted]]
cdf affy LPE ASSIGN cdf affy LPE ASSIGN • 906 views
ADD COMMENT

Login before adding your answer.

Traffic: 447 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6