Should tSNE from biol. replicates look alike?
1
0
Entering edit mode
Jose Guillen ▴ 10
@jose-guillen-6016
Last seen 10 days ago
Spain

Enter the body of text here

triplicates

Hello,

I have 1 "file" that contains scRNAseq data from cells derived from 3 mice, each labelled with one CMO. The three mice same condition (PBS), where labeled (CMO) and pooled and there was one seq run (1batch, am I right?).

I demultiplexed the 10x data using cell ranger.

I'm using bioconductor following this book/guideline: https://bioconductor.org/books/3.15/OSCA.multisample/human-pbmcs-10x-genomics.html#quality-control

My question is: should the tSNE from biological replicates look somehow similar? I'm thinking in shape but also number of clusters. How can I be confident that cluster changes after treatment are due to treatment if there is such "variability" in my PBS triplicates?

I hope the question makes sense

Sorry if this has been questioned before Cheers Jose G

scRNAseq SingleCellExperiment batchelor • 181 views
ADD COMMENT
2
Entering edit mode
@james-w-macdonald-5106
Last seen 1 hour ago
United States

You shouldn't expect t-SNE plots from different mice to look similar. Simply re-running t-SNE on the same sample will give different results, let alone on different samples. Note that the three samples in the book chapter that you are following don't look similar.

Login before adding your answer.