Posts by rosano

<prev • 5 results • page 1 of 1 • next >
0
votes
1
answer
108
views
1
answers
Comment: C: Scalability of emptyDrops() running times
... Thank you very much for your detailed response, and apologies about the very very late reply... I was delaying this answer until having some feedback on usage of this `BPPARAM` parameter, however, in the end I have not had the time yet to test and play around with it. Nonetheless, I plan to do so in ...
written 3 months ago by rosano0
0
votes
1
answer
161
views
1
answers
Comment: C: Recommendations for running DropletUtils::swappedDrops() on multiplexed samples
... Thank you very much for your answers and for detailing the experiment setup once more. We do not intend to mix extra samples into the multiplexing, but will always chose a setup as you describe here: > Now, the simplest case in which swappedDrops will work is: - 5' libraries for samples A-F are ...
written 4 months ago by rosano0
0
votes
1
answer
108
views
1
answer
Scalability of emptyDrops() running times
... Hi all, Currently I am using emptyDrops() for calling cells after applying swappedDrops() to perform barcode swapping removal of several 10X scRNA datasets. After experiencing long running times for emptyDrops() on these data, I was wondering about the scalability of the function's performance. A ...
dropletutils emptydrops written 4 months ago by rosano0 • updated 4 months ago by Aaron Lun24k
0
votes
1
answer
161
views
1
answers
Comment: C: Recommendations for running DropletUtils::swappedDrops() on multiplexed samples
... Dear both, Thank you very much for your quick reply and for the detailed explanations! So, as long as we avoid an intermixing of samples for the multiplexing (between libraries, as described in your alternative scheme with 6 mixed samples), swappedDrops should be able to correctly compare the sampl ...
written 4 months ago by rosano0
1
vote
1
answer
161
views
1
answer
Recommendations for running DropletUtils::swappedDrops() on multiplexed samples from multiple libraries
... Hi all, Regarding the following passage from the description of swappedDrops() from package DropletUtils: *“In files produced by CellRanger version 3.0, an additional per-molecule field is present indicating the (c)DNA library from which the molecule was derived. Library preparation can be perform ...
dropletutils swappeddrops written 4 months ago by rosano0 • updated 4 months ago by Aaron Lun24k