dependence of log2-ratios on scanning sensitivity?
1
0
Entering edit mode
@kamila-naxerova-2628
Last seen 10.3 years ago
Hi all, I am analyzing a bunch of miRNA arrays (Exiqon, dual channel, Hy3/Hy5). I am confused about the following issue.... Please apologize potential naivete, I have practically no experience with two-color designs. The chips have so called "Hy3 landing" lights, i.e. Hy3-labeled capture probes that help position the array for scanning. The mean intensity of these landing lights is very different between arrays (I assume that means slides were scanned with different sensitivity). First I thought that I don't have to worry about variable brightness among the arrays - I hybridized the exact same reference to all of them. But then I computed the correlation of all "real", intra-array normalized probe log2-ratios with the Hy3 landing light brightness... and the distribution has a disconcerting peak around 0.5. Am I missing something obvious? Thanks a lot. Kamila
miRNA miRNA • 979 views
ADD COMMENT
0
Entering edit mode
@wolfgang-huber-3550
Last seen 3 months ago
EMBL European Molecular Biology Laborat…
Dear Kamila, I don't know what exactly your normalisation did to obtain your "real, intra-array normalized probe log2-ratios", but it is a common challenge of two-color arrays to do good background correction, and if the background intensities are quite different between different arrays and the background correction is not adequate, this might indeed lead to the kind of problem you describe. In general it is good practice to not vary anything that might change the distribution of the data (such as scanner settings, labeling efficiency, amount of CIP'ed RNA) between arrays, because post hoc data normalisation will at best imperfectly remove these variations. Best wishes Wolfgang ------------------------------------------------------------------ Wolfgang Huber EBI/EMBL Cambridge UK http://www.ebi.ac.uk/huber Naxerova wrote: > Hi all, > > I am analyzing a bunch of miRNA arrays (Exiqon, dual channel, Hy3/Hy5). I > am confused about the following issue.... Please apologize potential > naivete, I have practically no experience with two-color designs. > > The chips have so called "Hy3 landing" lights, i.e. Hy3-labeled capture > probes that help position the array for scanning. The mean intensity of > these landing lights is very different between arrays (I assume that means > slides were scanned with different sensitivity). > > First I thought that I don't have to worry about variable brightness among > the arrays - I hybridized the exact same reference to all of them. But > then I computed the correlation of all "real", intra-array normalized > probe log2-ratios with the Hy3 landing light brightness... and the > distribution has a disconcerting peak around 0.5. Am I missing something > obvious? > > Thanks a lot. > Kamila > > _______________________________________________ > Bioconductor mailing list > Bioconductor at stat.math.ethz.ch > https://stat.ethz.ch/mailman/listinfo/bioconductor > Search the archives: http://news.gmane.org/gmane.science.biology.informatics.conductor
ADD COMMENT
0
Entering edit mode
Dear Wolfgang, thanks for your reply. To obtain the intra-array normalized values, I followed the simplest possible approach, i.e. I did the following: targets = readTargets("TargetExiqon.txt") RG = read.maimages(targets, source="genepix") MA = normalizeWithinArrays(RG,method="loess") Can you recommend some alternatives (vsn, of course, and anything else)? I have tried the normalization provided in the marray package, but that seems to be largely similar, only maNorm(raw,norm="loess") returns normalized data with many more missing values than normalizeWithinArrays, 4608 missing values vs. 23 for limma- I don't understand what the difference in loess implementation here is. I have noticed that there are relatively large differences in PMT gain across my chips. Could that be an explanation? I suppose if that is the case, I will not be able to fix the problem computationally? Thanks a lot, Kamila Wolfgang Huber wrote: > Dear Kamila, > > I don't know what exactly your normalisation did to obtain your "real, > intra-array normalized probe log2-ratios", but it is a common > challenge of two-color arrays to do good background correction, and if > the background intensities are quite different between different > arrays and the background correction is not adequate, this might > indeed lead to the kind of problem you describe. > > In general it is good practice to not vary anything that might change > the distribution of the data (such as scanner settings, labeling > efficiency, amount of CIP'ed RNA) between arrays, because post hoc > data normalisation will at best imperfectly remove these variations. > > Best wishes > Wolfgang > > ------------------------------------------------------------------ > Wolfgang Huber EBI/EMBL Cambridge UK http://www.ebi.ac.uk/huber > > > Naxerova wrote: >> Hi all, >> >> I am analyzing a bunch of miRNA arrays (Exiqon, dual channel, >> Hy3/Hy5). I >> am confused about the following issue.... Please apologize potential >> naivete, I have practically no experience with two-color designs. >> >> The chips have so called "Hy3 landing" lights, i.e. Hy3-labeled capture >> probes that help position the array for scanning. The mean intensity of >> these landing lights is very different between arrays (I assume that >> means >> slides were scanned with different sensitivity). >> >> First I thought that I don't have to worry about variable brightness >> among >> the arrays - I hybridized the exact same reference to all of them. But >> then I computed the correlation of all "real", intra-array normalized >> probe log2-ratios with the Hy3 landing light brightness... and the >> distribution has a disconcerting peak around 0.5. Am I missing something >> obvious? >> >> Thanks a lot. >> Kamila >> >> _______________________________________________ >> Bioconductor mailing list >> Bioconductor at stat.math.ethz.ch >> https://stat.ethz.ch/mailman/listinfo/bioconductor >> Search the archives: >> http://news.gmane.org/gmane.science.biology.informatics.conductor > > >
ADD REPLY
0
Entering edit mode
Hi. On Feb 3, 2008 10:31 AM, Kamila Naxerova <knaxerova at="" chip.org=""> wrote: > Dear Wolfgang, > thanks for your reply. To obtain the intra-array normalized values, I > followed the simplest possible approach, i.e. I did the following: > > targets = readTargets("TargetExiqon.txt") > RG = read.maimages(targets, source="genepix") > MA = normalizeWithinArrays(RG,method="loess") > > Can you recommend some alternatives (vsn, of course, and anything else)? > I have tried the normalization provided in the marray package, but that > seems to be largely similar, only maNorm(raw,norm="loess") returns > normalized data with many more missing values than > normalizeWithinArrays, 4608 missing values vs. 23 for limma- I don't > understand what the difference in loess implementation here is. > > I have noticed that there are relatively large differences in PMT gain > across my chips. Could that be an explanation? I suppose if that is the > case, I will not be able to fix the problem computationally? Having different PMT settings will affect the scale of the pixel intensities in the scanned images. If the PMT is set too hight, pixel values will get censored to the maximum value of the scanner, typically 65535. Since the spot/feature signal is an average of all pixels, this "saturation/censoring" effect comes into play at a slightly higher PMT at the feature level compared to the pixel level, especially when a robust average is used. If you set the PMT too low, the signal might drown in the "background" noise. However, from a study on Axon and Agilent two-color scanners, we found that after controlling for different scale factors (and offset), the exact PMT setting is not that important, as long as it is not extremely low or extremely high (which is rarely the case). In other words, you should not worry too much about your PMT settings. For more details about our study, see H. Bengtsson, G. J?nsson and J. Vallon-Christersson, Calibration and assessment of channel-specific biases in microarray data with extended dynamical range, BMC Bioinformatics, 2004, 5:177. That paper also show how to estimate the offset added by the scanner, given that you scan more than one time at different PMTs. If you control for the scanner offset, the main effect of the PMT setting goes a way and only a scale factor remains which is very is to estimate and adjust for. Curve-fit normalization, e.g. lowess, loess, smooth spline and so on, will *not* correct for scanner offset or other types of offset (the "background" that Wolfgang refers to). Offset is the main cause of observing curvature in log-ratio log-intensity plots. I would like to suggest to use a normalization method that explicitly tries to control for differences in offset and scale. The variance stabilizing normalization (vsn) method is one and affine normalization (aroma.light) is another. Hope this helps /Henrik > > Thanks a lot, > Kamila > > > Wolfgang Huber wrote: > > Dear Kamila, > > > > I don't know what exactly your normalisation did to obtain your "real, > > intra-array normalized probe log2-ratios", but it is a common > > challenge of two-color arrays to do good background correction, and if > > the background intensities are quite different between different > > arrays and the background correction is not adequate, this might > > indeed lead to the kind of problem you describe. > > > > In general it is good practice to not vary anything that might change > > the distribution of the data (such as scanner settings, labeling > > efficiency, amount of CIP'ed RNA) between arrays, because post hoc > > data normalisation will at best imperfectly remove these variations. > > > > Best wishes > > Wolfgang > > > > ------------------------------------------------------------------ > > Wolfgang Huber EBI/EMBL Cambridge UK http://www.ebi.ac.uk/huber > > > > > > Naxerova wrote: > >> Hi all, > >> > >> I am analyzing a bunch of miRNA arrays (Exiqon, dual channel, > >> Hy3/Hy5). I > >> am confused about the following issue.... Please apologize potential > >> naivete, I have practically no experience with two-color designs. > >> > >> The chips have so called "Hy3 landing" lights, i.e. Hy3-labeled capture > >> probes that help position the array for scanning. The mean intensity of > >> these landing lights is very different between arrays (I assume that > >> means > >> slides were scanned with different sensitivity). > >> > >> First I thought that I don't have to worry about variable brightness > >> among > >> the arrays - I hybridized the exact same reference to all of them. But > >> then I computed the correlation of all "real", intra-array normalized > >> probe log2-ratios with the Hy3 landing light brightness... and the > >> distribution has a disconcerting peak around 0.5. Am I missing something > >> obvious? > >> > >> Thanks a lot. > >> Kamila > >> > >> _______________________________________________ > >> Bioconductor mailing list > >> Bioconductor at stat.math.ethz.ch > >> https://stat.ethz.ch/mailman/listinfo/bioconductor > >> Search the archives: > >> http://news.gmane.org/gmane.science.biology.informatics.conductor > > > > > > > > _______________________________________________ > Bioconductor mailing list > Bioconductor at stat.math.ethz.ch > https://stat.ethz.ch/mailman/listinfo/bioconductor > Search the archives: http://news.gmane.org/gmane.science.biology.informatics.conductor >
ADD REPLY

Login before adding your answer.

Traffic: 809 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6