Typo in DESeq2 documentation?
1
0
Entering edit mode
@peter-langfelder-4469
Last seen 13 months ago
United States

DESeq2 manual (http://bioconductor.org/packages/release/bioc/vignettes/DESeq2/inst/doc/DESeq2.pdf) says, on page 34:

By default these log2 fold changes are the maximum a priori estimates after incorporating a zero-
centered Normal prior
...

Should the "a priori" above be "posterior", or am I missing something in Bayesian estimation theory?

Thanks,

Peter

deseq2 • 827 views
ADD COMMENT
0
Entering edit mode
@mikelove
Last seen 4 days ago
United States

Ha! yes, thanks again Peter. I just fixed this (in devel).

ADD COMMENT