Swish direction of comparison based on order of factors
1
0
Entering edit mode
Jean • 0
@1b3ec4d9
Last seen 2.4 years ago
Austria

Hi,

I noticed that the order of factors in swish(x="condition") analysis makes a difference in the sign of the log2fc values. My question is which factor level is the reference if for example one has two factors in the order MUTANT, WT for condition. My assumption is WT is actually the reference level so a positive log2fc indicates up-regulation relative to MUTANT and a negative log2fc indicates down-regulation. But it could also be the other way around.

Best,

Jean Elbers

fishpond • 974 views
ADD COMMENT
1
Entering edit mode
@mikelove
Last seen 16 hours ago
United States

hi Jean,

Thanks for the question, this wasn't explicitly stated in the documentation, so I've updated it, here are the new sections in man pages and vignette:

https://github.com/mikelove/fishpond/commit/87639eafb3301ec4cc5c91f6dce3fdfb8632d300

ADD COMMENT
0
Entering edit mode

Thank you that helps a lot!

ADD REPLY