Question: riboSeqR: criteria used to determine reading frames
0
gravatar for antonvila.s
4.2 years ago by
Spain
antonvila.s0 wrote:

Hi,

I'm having trouble to understand which criteria are used for the determination of the reading frame in roboSeqR. Is it the position of the 5' nucleotide relative to the START codon, the position of the first base of the A-site codon, other?

best,

Antón

riboseqr • 500 views
ADD COMMENTlink modified 4.1 years ago by Thomas J Hardcastle180 • written 4.2 years ago by antonvila.s0
Answer: riboSeqR: criteria used to determine reading frames
0
gravatar for Thomas J Hardcastle
4.1 years ago by
United Kingdom
Thomas J Hardcastle180 wrote:

A read that starts in frame with the A of the ATG will be in frame 0, that which starts in frame with the T will be in frame 1, et cetera.

ADD COMMENTlink written 4.1 years ago by Thomas J Hardcastle180