flowCore: 'truncate_max_range' argument in 'read.flowSet'
2
0
Entering edit mode
@lukas-weber-10656
Last seen 8 months ago
Boston University

Hi,

I have a question about reading in data from multiple FCS files with `read.flowSet` from the flowCore package.

By default, both `read.FCS` and `read.flowSet` truncate values outside the specified instrument measurement range. The `read.FCS` function (for a single FCS file) also includes an argument to disable this, `truncate_max_range = FALSE`, which I have found useful in case the measurement range hasn't been specified correctly. This was also discussed previously on this list, e.g. this question: readFCS truncates the data that is out of instrument range

However, there doesn't seem to be a similar argument in `read.flowSet` (for reading in multiple files). Is there any way to disable truncation of values with `read.flowSet`? I could simply use `lapply` and `read.FCS`, but it would be useful to have this option available directly within `read.flowSet`.

Best regards,

Lukas

flowcore • 1.6k views
ADD COMMENT
1
Entering edit mode
Jiang, Mike ★ 1.3k
@jiang-mike-4886
Last seen 3.2 years ago
(Private Address)

I've pushed the fix to flowCore 1.40.5. or you can `devtool::install_github("RGLab/flowCore", ref = "trunk")` if you can't wait until BioC build the release.

Alternatively, you can use 'read.ncdfFlowSet` which already supports this feature and is generally favored than 'read.flowSet' due to its scalability.

ADD COMMENT
0
Entering edit mode
@lukas-weber-10656
Last seen 8 months ago
Boston University

Great, thanks for the quick reply and update. I'll also look into using `read.ncdfFlowSet` in future.

Lukas

ADD COMMENT

Login before adding your answer.

Traffic: 671 users visited in the last hour
Help About
FAQ
Access RSS
API
Stats

Use of this site constitutes acceptance of our User Agreement and Privacy Policy.

Powered by the version 2.3.6